Английский язык для судовых электромехаников - страница 76

Шрифт
Интервал

стр.

9

Choose the proper translation. Most shaft generator design, а) самая большая конструкция валогенератора; б) конструкция само-

го большого валогенератора; в) конструкция большинства валогейе-раторов.

10


Choose the proper translation. Normal input generator operation, а) работа обычного входа генератора; б) обычная работа входного генератора; в) обычный ввод работающего генератора.

11


List a step-by-step procedure for starting the engine from the engine control room. Write 10 sentences.

Sum up your results. Time. . . Score. . . Mark. . .

THE NINTH TERM (20)


UNIT 4

E L F. CT R О NIC AUTOMATION

SECTION! (4-f-1 +4)

Bridge Manoeuvring System Text


Daily Use of the Bridge Manoeuvring System

1. Preparation and change over. Preparation and change over of the engine for the bridge control should be made in accordance with the instructions issued by the engine builder. The following points should be noted: The pump station for the hydraulic amplifier is started to provide oil pressure in the amplifier.

The automatic stop piston valve must be turned to the ‘'Service" position.

2. Control Panel.

Check that the test telegraph switches on the mimic diagram are in the "Normal” position.

3. Check also that the switch in the engine speed test unit is in the "Tacho” position. If this switch is left in the "Test'’ position, the unit lamp will light up. If a start attempt is made, registration of the engine’s turning will not take place and the tacho arid repeated start supervision unit (IRS) will register (lie missing tacho signal, and after 6 ry^tart blocking and a tacho failure alarm will be initiated. If the control system is not furnished with a TRS Unit, starting air will be admitted until the pressure switch is activated.

4. The overspeed, slow turning, load program and reversing level switches on the mimic diagram arc to be placed in the "On” normal position in order to incorporate these functions.

5. Check with the aid of incorporated voltmeter that all necessary voltages are present.

6. Check that the power supply switch is in the "Normal” position, if it is in the “Battery” position, the system will still he able to work, but normal running calls for the switch in the “Normal” position. Remember to press button if a change over from “Battery” to “Normal” becomes necessary.

7. Examine whether any of the lamps in the signal panel for emergency are lit up. If some are lit, the indicated fault should be remedied.

8. Check whether the safety panel shows any alarms or any shut- or slow-down channels. The lamps in the panel are extinguished under normal conditions. If an alarm occurs, the lamps will light up strongly. If a channel has been “pushed" out of working order, the lamp will continue to light up weakly provided there is no alarm on the channel. If an alarm occurs on a channel, the lamp will also light up strongly in this condition.

9. When these preparations have been carried out the system is read',’ for automatic control.

SECTION 2

(3+1+3)

Text


Precautions at Siow- and Shut-Downs

1. In the event of a slow- or shut-down occurring, the appropriate lamps light up on the bridge telegraph and in the signal panel for emergency in the control room. If, with regard to the safety of the vessel, it proves necessary to start the engine again, the “cancel'' button on the bridge telegraph can be activated. Since this is an emergency function, it will immediately release an alarm in the engine room. If it is not imperative for the engine to run, the fault should be rectified before the engine is stated again. When the fault has been rectified, the reset button is pressed on the control room. When this button is activated, the slow down circuit will he reset, and the engine will be automatically regulated up to the position of the handle. In the case of a shut-down, the engine will be automatically restarted after reset and the engine will regulate up to the value at which the bridge telegraph is set to.

2. Reset of a slow- or shut-down can also take place from the bridge by placing the telegraph on the bridge in stop position. An automatic reset order is thereby transmitted to the control panel, and' if the slow- or shut-down condition has vanished automatic restart can be done by placing the telegraph in an arbitrary position.


стр.